Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012 199
System Commissioning Chapter 6
2. Expand RSLinx Enterprise and double-click
Communication Setup.
The Communication Setup window opens.
Configure Design (Local) Communication
The local tab in
Communication Setup window
reflects the view of the
topology from the RSLinx
Enterprise server on the
development computer. In this
example, the development
computer is configured to
communicate with a L62S
GuardLogix controller via the
Ethernet network.
1. Expand your systems
Ethernet network.
2. Expand your systems Ethernet module.
3. Expand your controller bus or backplane.
4. Select your systems controller.
In this example, the controller is a ControlLogix 1769-L63 controller.
5. Click Add.