Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012 237
Logic Program Overview Appendix A
Device and Application Status Rung Tags and Logic
The device and application status rungs provide feedback information to the machine module and consists of
these components.
Figure 35 - Device Module Status
Figure 36 - Application Module Status
The status bits are set in the monitor routine of the corresponding modules. These status bits are vital to the
machine module, as they are used to determine the overall status of the machine. They help the machine
transition between states or detect a fault and respond accordingly. All of the module status information is
summarized in the monitor routine of the machine module.