Appendix A Logic Program Overview
Table 13 - Module Routine Overview
Logic Module Type Routine Function
Machine
R00_Main Dispatch routine, calls all of the other routines in the program.
R01_PowerUp Initializes parameters following powerup or controller first scan.
R02_Monitor
Summarizes the status from all of the dependent modules (for example, application and device
modules).
Detects Abort and/or Stop conditions.
Provides machine status information to HMI terminal.
R03_Control
Provides main interface with HMI terminal requests (for example, Start/Stop/Clear Faults
pushbuttons).
Contains the state machine logic.
Application
R00_Main Dispatch routine, calls all of the other routines in the program.
R01_PowerUp Initializes parameters following powerup or controller first scan.
R02_Monitor
Summarizes the status for the application module (for example, OK, Ready, Running, Stopped).
Detects module faults (for example, Failed to RESET, Failed to RUN).
R03_Control
Receives machine commands and initiates the corresponding sequences (for example, RESET, RUN and
STOP sequences).
R04_Reset Contains the RESET sequence logic, used to prepare the application to run.
R10_ApplicationCode
Typical location for the application specific logic.
Contains the RUN and STOP sequences.
FANUC CNC
R00_Main Dispatch routine, calls all of the other routines in the program.
R01_PowerUP Initializes parameters following powerup or controller first scan.
R02_Monitor
Summarizes the status for the device module (for example, OK, Ready, Reset).
Detects module faults (for example, Failed to RESET, Failed to CLEAR, Module Not
Ready).
Contains the faceplate add-on instruction (Add-On Instruction) for the HMI terminal
faceplate.
R03_Control
Receives machine commands and initiates the corresponding sequences (for example,
RESET and ABORT sequences).
R04_Reset_Abort
Contains place holder for application specific reset logic if required.
Contains the ABORT sequence, which makes sure that the drives contained within the
module are stopped and disabled. The ABORT sequence also makes sure that other
devices are placed into a desired state.
PowerFlex
R00_Main Dispatch routine, calls all of the other routines in the program.
R01_PowerUP Initializes parameters following powerup or controller first scan.
R02_Monitor
Summarizes the status for the device module (for example, OK, Ready, Reset).
Detects module faults (for example, Failed to RESET, Failed to CLEAR, Module Not Ready).
Contains the faceplate add-on instruction (Add-On Instruction) for the HMI terminal faceplate.
R03_Control
Receives machine commands and initiates the corresponding sequences (for example, RESET and ABORT
sequences).
R04_Reset_Abort
Contains place holder for application specific reset logic if required.
Contains the ABORT sequence that makes sure that the drives contained within the module are
stopped and disabled. The ABORT sequence also makes sure that other devices are placed into a
desired state.