268 Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012
Appendix D Logix Communication and Controller Configuration
The Request History field displays
all of the devices in your network
that need IP addresses.
The EtherNet/IP (MAC) addresses
correspond to the pre-loaded
addresses and typically are marked
on the device labels.
3. Double-click a request from one of
the devices.
4. Enter a unique IP address for each
device.
5. Click OK.
If you are not on an isolated
network, obtain the IP addresses
from your network administrator.
6. Repeat step 3step 5 for each device, except the PanelView Plus terminal.
7. Select the first device in the Relation
List field.
8. Click Disable BOOTP/DHCP.
9. Repeat step 7 and step 8 for all
devices except the PanelView Plus
terminal.
10. Close the BOOTP/DHCP utility.
If prompted to save changes, click
No.
IMPORTANT
If you cycle power, the device will not retain its IP
address unless you disable BOOTP/DHCP.
Vista de pagina 267