88 Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012
Chapter 4 GuardLogix Configuration
3. Configure the new controller.
a. From the Type pull-down menu,
choose the controller type.
b. From the Revision pull-down
menu, choose the revision.
c. Type the file name in the Name
field.
d. From the Chassis Type pull-down
menu, choose the chassis.
e. Enter the Logix processor slot
(leftmost slot = 0).
4. Click OK.
5. From the Edit menu, choose
Controller Properties.
The Controller Properties dialog
box opens.
6. Click the Date/Time tab.
7. Check Enable Time
Synchronization.
This enables time
synchronization for the
controller.
8. Click OK.