38 Rockwell Automation Publication MPMA-UM001B-EN-P - November 2010
Chapter 4 Mounting and Connecting the MP-Series Integrated Multi-axis Linear Stage
2. Torque the ground screw at the lower stage to 2 Nm (18 lbin.).
3. Form a drip loop in each cable at a point directly before it attaches to the
motor.
M5 x 0.8 -6H
Ground Screw
Braided Ground Wire 12 mm (0.5 in.) min.
Lug
Align Flat Surfaces
Power/Brake
Connector
Feedback
Connector
Drip Loop
in Cable