Publication 1760-UM003A-EN-P - September 2005
Pico GFX Control Commands 7-27
Block Transfer: BT01 – BT32
Table 6.111 Telegram Structure
Byte Meaning Value (hex), sent by
Maste
r
Slav
e
Master Slave
Attribute ID
Read 92
Write B2
0 Response:
Read successful C2
Write successful C1
Command rejected C0
0 1 Type 26 26
1 2 Instance 01 – 20 01 – 20
2 3 Index Table 6.112 Table 6.112
3 – 6 4 – 7 Data 1 – 4
Read operation 00 depending on index,
Table 6.113, 6.114
Write operation depending on index,
Table 6.113, 6.114
00
Table 6.112 Operand overview
Index
(hex)
Operand read write
00 Bit IO, Table 6.113 x
01 Mode, Table 6.114 x
02 Source range 1 I1 x
c
(1)
(1) The value can only be written if it is assigned to a constant in the program.
03 Target range 2 I2 x
c
(1)
04 Number of elements to compare: max. 192 bytes NO x
c
(1)
TIP
The data for index 2 and 3 is transferred as a 32-bit
value in Intel format (Data 1 – Low Byte .. Data 2 -
High Byte).