Rockwell-automation 1760-DNET Pico DeviceNet Communications Module Use Manual de usuario Pagina 108

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 168
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 107
Publication 1760-UM003A-EN-P - September 2005
7-28 Pico GFX Control Commands
Boolean operation: BV01 – BV32
Table 6.113 Index 0 – Bit IO
Bit76543 2 1 0
FB input Data 1 –––––
T
(3)
(3) Transfer of the source address specified at I1 to the target address specified at I2 on rising edge.
FB output Data 3 –––––
E3
(1)
(1) Status 1 if the number of elements exceeds the source or target range.
E2
(2)
(2) Status 1 if the source and target range overlap.
E1
(4)
(4) Status 1 if the source or target range are outside of the available marker range (offset error)
Table 6.114 Index 1 - Mode
Data 1
(hex)
Mode
00 INI: Initialises the target range with a byte value stored at the source
address.
01 CPY: Copies a data block from a source to a target range. Data block size
is specified at NO.
Table 6.115 Telegram Structure
Byte Meaning Value (hex), sent by
Master Slave Master Slave
Attribute ID
Read 92
Write B2
0 Response:
Read successful C2
Write successful C1
Command rejected C0
0 1 Type 13 13
1 2 Instance 01 – 20 01 – 20
2 3 Index Table 6.116 Table 6.116
Vista de pagina 107
1 2 ... 103 104 105 106 107 108 109 110 111 112 113 ... 167 168

Comentarios a estos manuales