Rockwell-automation 1760-DNET Pico DeviceNet Communications Module Use Manual de usuario Pagina 75

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 168
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 74
Publication 1760-UM003A-EN-P - September 2005
Application Examples for Pico 6-31
Example:
Data 1 (Byte 4) = 0x03 l The values for the year time switch of
channels A and B appear in the parameter menu.
Channel A, index 11/12
Index 0x11 channel A timepoint of switch on
Index 0x12 channel A timepoint of switch off
Data 1 (Byte 4) – day
Data 2 (Byte 5) – month
Data 3 (Byte 6) – year
Example:
The year time switch channel A should be switched on at the
21.04.2004.
Channel D x
c
(1)
41 Time point ON x
c
(1)
42 Time point OFF x
c
(1)
(1) The value can only be written if it is assigned to a constant in the program.
In the data bytes Data 1 – Data 3 the switching points are transferred.
Table 6.60 Index 00 – Parameters
Meaning Bit76543210
Appears in the
parameter menu
Channel A 0/1
Channel B 0/1
Channel C 0/1
Channel D 0/1
Unused bits
Table 6.61 Index 01 – Control byte
Data 1 Bit76543210
FB output
Q1
(1)
(1) Status 1 if count condition is fulfilled.
Table 6.59 Operand overview
Index
(hex)
Operand Read Write
Vista de pagina 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 167 168

Comentarios a estos manuales