Publication 1760-UM003A-EN-P - September 2005
Pico GFX Control Commands 7-47
The data in the following table is shown in the Motorola format
although it is actually transferred in Intel format.
Example
The channel A parameters of 7-day time switch HW19 are to be read.
Table 6.152 Operand overview
Index
(hex)
Operand read write
00 Bit IO Table 6.153 x
01 Mode/Parameter
02 Parameters Table 6.154 x
Channel A
03 Channel B
04 Channel C
05 Channel D
Table 6.153 Index 0 – Bit IO
FB output Data 3
Bit76543 2 1 0
–––––
Q
(1)
(1) Status 1 if the switch-on condition is fulfilled.
Table 6.154 Index 2 – 5, Parameter channels A – D
Bit7 65432 10765 4 3 2 1 0
Date 2 Date 1
ON
d4
(1)
(1) d5 to d0: Weekday (0 = Sunday to 6 = Saturday)
d3 d2 d1 d0
h4
(2)
(2) h4 to h0: Hour (0 to 23)
h3 h2 h1 h0
m5
(3)
(3) m5 to m0: Minute (0 to 59)
m4 m3 m2 m1 m0
Weekday Hour Minute
Bit7 65432 10765 4 3 2 1 0
Date 4 Date 3
OFF d4 d3 d2 d1 d0 h4 h3 h2 h1 h0 m5 m4 m3 m2 m1 m0
Weekday Hour Minute