
Publication 1760-UM003A-EN-P - September 2005
6-24 Application Examples for Pico
Example:
Data 1 (Byte 4) = 0x07
Meaning:
The values appear in the Parameter menu. The counter is used in the
mode of the frequency meter. The counter setpoint 1 is not assigned
to a constant and cannot therefore be written to.
Table 6.44 Operand overview
Index
(hex)
Operand Read Write
00 Parameters Table 6.45 x
01 Control byte Table 6.46 x
02 Process variable
S1
(1)
(1) A 16-bit value is transferred in data bytes Data 1 – Data 2. It should be remembered that
Data 1 is the low byte and Data 2 the high byte.
x
c
(2)
(2) The value can only be written if it is assigned to a constant in the program.
03 Counter setpoint 2
S2
(1)
x
c
(2)
Table 6.45 Index 00 – Parameters
Meaning Bit76543210
Appears in the parameter menu
Yes/no 0/1
Counter mode
FB not used 0 0
Up/down counter (N) 0 1
High-speed up/down counter (H) 1 0
Frequency counter (F) 1 1
Use as constant and therefore can be written to
Counter setpoint S1 0/1
Unused bits – – – –
Table 6.46 Index 01 – Control byte
Data 1 Bit76543210
FB output – – – –
C
(1)
(1) Count coil, counts on every rising edge
RE
(2)
(2) Reset, the timing relay is reset (reset coil)
D
(3)
(3) Count direction: 0 = up counting, 1 = down counting
Q1
(4)
(4) Switch contact
Comentarios a estos manuales