Publication 1760-UM003A-EN-P - September 2005
Application Examples for Pico 6-29
Meaning:
The values appear in the Parameter menu. The time is used in the
impulse transmitter mode with the Second time base. The time
setpoint S1 is assigned a constant and the time setpoint S2 is assigned
a variable such as I7, I8 C2...etc.
Explanation:
Data 1 = 4C
Data 2 = 06
l resulting 16-bit value = 064C
hex
= 1612
dec
Table 6.55 Index 01 – Control byte
FB input/output Data 3
Bit76543 2 1 0
ST
(1)
(1) Stop, the timing relay is stopped (Stop coil)
RE
(2)
(2) Reset, the timing relay is reset (reset coil)
EN
(3)
(3) Enable, the timing relay is started (trigger coil)
Q1
(4)
(4) Switch contact
Table 6.56 Read Time Setpoint 1
Byte Meaning Value (hex), sent by
Master Slave
0 Command: Read 89
Response: read successful C2
1 Type 8E 8E
2 Instance 00 00
3 Index 03 03
4 Data1 00 4C
5 Data 2 00 06
6 Data 3 00 00
7 Data 4 00 00
Table 6.57 Set Time
millisecond s 16120 ms 16.120 s
Seconds M:S 1620 s 26:52 Minutes
Minute H:M 1612 min 67:04 Hours