Publication 1760-UM003A-EN-P - September 2005
Pico GFX Control Commands 7-29
3 – 6 4 – 7 Data 1 – 4
Read operation 00 depending on index,
Table 6.117 and 6.118
Write operation depending on index,
Table 6.117 and 6.118
00
Table 6.116 Operand overview
Index
(hex)
Operand read write
00 Bit IO, Table 6.117 x
01 Mode, Table 6.118 x
02 First operand I1 x
c
(1)
(1) The value can only be written if it is assigned to a constant in the program.
03 Second operand I2 x
c
(1)
04 Operation result QV x
TIP
The data for index 2 to 4 is transferred as a 32-bit value in Intel
format (Data 1 – Low Byte to Data 4 – High Byte).
Table 6.117 Index 0 – Bit IO
FB output Data 3
Bit 765432 1
––––––
ZE
(1)
(1) Status 1 if the value of the function block output QV (the operation result) equals zero
Table 6.118 Index 1 - Mode
Data 1
(hex)
00 AND And sequence
Table 6.115 Telegram Structure
Byte Meaning Value (hex), sent by
Master Slave Master Slave