Publication 1760-UM003A-EN-P - September 2005
6-16 Application Examples for Pico
Example:
Data 1 = 52
hex
l Q2, Q5 and Q7 are active.
Inputs/outputs of PicoLink: R1 – R16/S1 – S8
This service allows you to read the local R and S data and the data of
the NET stations (1 – 8) transferred via PicoLink, again from the
relevant Pico image.
Q2 0/1
.. ..
Q8 0/1
Table 6.28 Telegram Structure
Byte Meaning Value (hex), sent by
Master Slave Master Slave
Attribute ID: Read 88
0 Response:
Read successful C2
Command
rejected
C0
(1)
(1) Possible causes page 6-34
0 1 Len 01 01
1 2 Type
for R data 88 88
for S data 89 89
2 3 Index 00 00
3 4 Data 1 (Low Byte) 00 Table 6.29
4 5 Data 2 (Low Byte) 00 Table 6.29
5 – 6 6 – 7 Data 3 – 4 00 00
Table 6.29 Byte 3 to 4 (master) or Byte 4 to 5 (slave): Data 1 to 2
Data 1 Bit76543210
RW SW
R1 S1 0/1
R2 S2 0/1
... ... ...
Table 6.27 Byte 4: Data 1