Rockwell Automation Publication 280E-UM001B-EN-P – July 2012 119
Bulletin 280E/281E/284E Programmable Parameters Chapter 7
Breaker Type
This parameter identifies the Bulletin
140M used in this product.
0 = 140M-D8N-C10
1 = 140M-D8N-C25
Parameter Number 22
Access Rule GET/SET
Data Type BOOL
Group Basic Status
Units
Minimum Value 0
Maximum Value 1
Default Value 0
Base Enclosure
Indicates the ArmorStart Base unit
enclosure rating.
Bit 0 = IP67
Bit 1 = Reserved
Bit 2…15 = Reserved
Parameter Number 56
Access Rule GET
Data Type WORD
Group Basic Status
Units
Minimum Value 0
Maximum Value 1
Default Value 1
Base Options
Indicates the options for the
ArmorStart Base unit.
Bit 0 = Output Fuse
Bit 1 = Reserved
Bit 2 = CP Fuse Detect
Bits 3…7 = Reserved
Bit 8 = 10A Base
Bit 9 = 25A Base
Bit 10…15 = Reserved
Parameter Number 57
Access Rule GET
Data Type WORD
Group Basic Status
Units
Minimum Value 0
Maximum Value 517
Default Value 0
Wiring Options
Bit 0 = Conduit
Bit 1 = Round Media
Bit 2 = 28xG Gland
Bits 3…15 = Reserved
Parameter Number 58
Access Rule GET
Data Type WORD
Group Basic Status
Units
Minimum Value 0
Maximum Value 4
Default Value 0