Rockwell-automation 284E ArmorStart with EtherNet/IP - User Manual Manual de usuario Pagina 203

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 348
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 202
Rockwell Automation Publication 280E-UM001B-EN-P - July 2012 203
Chapter 8
How to Configure an Explicit Message
Programming ControlLogix®
Explicit Message
Explicit Messaging with ControlLogix
In the ControlLogix platform, explicit messaging can be done easily from within
a logic program. The request and response is configured within the MSG
function. The MSG function can be found in the Input/Output tab of
RSLogix 5000.
Setting Up the MSG Instruction
A tag name must be given to the MSG function before the rest of the information
can be defined. In this example a tag was created with the name explicit_mess.
After the instruction has been named, click on the gray box to define the rest
of the instruction.
Figure 75 - MSG Function Found in the Input/Output Tab
Formatting an Explicit
Message
ControlLogix scanners and bridges accommodate both downloading Explicit
Message Requests and uploading Explicit Message Responses. The message
format is shown in Figure76.
Vista de pagina 202
1 2 ... 198 199 200 201 202 203 204 205 206 207 208 ... 347 348

Comentarios a estos manuales

Sin comentarios