Rockwell Automation Publication 280E-UM001B-EN-P – July 2012 157
Bulletin 280E/281E/284E Programmable Parameters Chapter 7
Control Source
Displays the source of the Start
Command and Speed Reference.
2 = 2-wire
3 = 2-wire Level Sensitive
4 = 2-wire High Speed
5 = RS485 (DSI) Port
9 = Jog
Valid Speed Commands for the
Bulletin 284E ArmorStart are the
following:
1 = Internal Frequency
4 = Preset Freq x
5 = Comm Port (RS485 (DSI))
6 = StepLogic Control
9 = Jog Freq
Parameter Number 112
Related Parameters
136, 138, 151…154 (Digital In x
Sel) must be set to Option 4, 169,
170…177 (Preset Freq x),
240…247 (StpLogic x)
Access Rule GET
Data Type UINT
Group Drive Display
Units 1
Minimum Value 0
Maximum Value 9
Default Value Read Only
Contrl In Status
Status of control inputs. These can be
used in DeviceLogix.
Bit 0 = Start/Run FWD Input
Bit 1 = Direction/Run REV Input
Bit 2 = Stop Input
Bit 3 = Dynamic Brake Transistor On
Parameter Number 113
Related Parameter 102, 134, 135
Access Rule GET
Data Type UINT
Group Drive Display
Units 1
Minimum Value 0
Maximum Value 1
Default Value Read Only
Dig In Status
Status of the control terminal block
digital inputs:
Bit 0 = Digital In 1 Sel
Bit 1 = Digital In 2 Sel
Bit 2 = Digital In 3 Sel
Bit 3 = Digital In 4 Sel
Parameter Number 114
Related Parameter 151…154
Access Rule GET
Data Type UINT
Group Drive Display
Units 1
Minimum Value 0
Maximum Value 1
Default Value Read Only