298 Rockwell Automation Publication 280E-UM001B-EN-P – July 2012
Appendix B CIP Information
The following class attributes are supported:
Four instances of the DPI Fault Object are supported. The have the following
instance attributes:
The following services are supported:
Attribute ID Access Rule Name Data Type Value
1 Get Class Revision UINT 1
2 Get Number of Instances UINT 4
3 Get Fault Cmd Write USINT 0 = NOP, 1 = Clear Fault, 2 = Clear Flt Queue
4 Get Fault Instance Read UINT
The instance of the Fault Queue Entry containing
information about the Fault that tripped the Device.
6 Get Number of Recorded Faults UINT The number of Faults recorded in the Fault Queue.
Attribute ID Access Rule Name Data Type Value
0 Get Full/All Info Struct of: —
— — Fault Code UINT See table below.
— — Fault Source Struct of: —
— — DPI Port Number USINT 0
— — Device Object Instance USINT 0x2c
— — B Fault Text BYTE[16] See table below.
— — Fault Time Stamp Struct of: —
— — Timer Value ULDINT —
— — Timer Description WORD —
— — Help Object Instance USINT —
—— Fault Data —
1GetBasic Info Struct of: —
— — Fault Code UINT See table below.
— — Fault Source Struct of: —
— — DPI Port Number USINT 0
— — Device Object Instance USINT 0x2C
— — Fault Time Stamp Struct of: —
— — Timer Value ULINT —
— — Timer Description WORD —
3 Get Help Text STRING See table below.
Service Code
Implemented for:
Service NameClass Instance
0x0E Yes Yes Get_Attribute_Single
0x10 Yes No Set_Attribute_Single
Comentarios a estos manuales