Chapter 5 –Programming
5-34
Output Configuration Group (cont.)
g
ut
]
Parameter # 25 Factory Default “Frequency”
g
ut
]
Parameter Type Read & Write
This parameter selects the value to which the 0-10V DC
Units None Setting ‘‘Frequency”
0 to [Maximum Freq]
i
a
am
t
l
ct
t
al
to w
ic
t
0-10V
analog output at TB2-5 terminal is proportional.
‘‘Current”
0 to 200% of Rated Drive Output Current)
‘‘Bus Volts”
0 to Maximum Bus Voltage– 410V/230V Drives
815V/460V Drives
‘‘Power”
0 to 200% of Drive Rated OutputPower
b
v
F
q V
]
Parameter # 77 Factory Default 0 Hz
b
v
F
q V
]
Parameter Type Read & Write Minimum 0 Hz
This parameter is used when [Output 1 Config] or
[Output 2 Config] is set to ‘‘Above Freq” to indicate when
the drive is operating above the specified frequency
setting.
Units Hertz Maximum 400 Hz
IMPORTANT: This parameter can not be pro-
grammed while the drive is running.
b
v
Cu
V
]
Parameter # 142 Factory Default 0 % of Drive Rated Current ➀
b
v
Cu
V
]
Parameter Type Read & Write Minimum 0 % of Drive Rated Current ➀
This parameter is used when [Output 1 Config] or
[Output 2 Config] is set to ‘‘Above Curr” to indicate when
the drive output current exceeds this value.
Units 1% Maximum 150% of Drive Rated Current ➀
➀ The drive rated output current is based on three phase input ratings. See page 5-13
for Single Phase Input Rating instructions.