Rockwell-automation 1305 AC Drive, Firmware 1.01-3.00 User Manual Manual de usuario Pagina 119

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 162
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 118
Chapter 5 –Programming
5-51
This group contains parameters that can be used to display a drive parameter in ‘‘User Units.”
Process Display
[Pro
c
e
ss
Par
]
Parameter # 127 Factory Default 1
[Pro
c
e
ss
Par
]
Parameter Type Read & Write Minimum 1
This parameter should be set to the number of the
parameter whose scaled value will be displayed on
Line 1 of the HIM Display Panel when in process mode.
Units Numeric Maximum Max. Parameter Number
[Pro
c
e
ss
S
c
ale
]
Parameter # 128 Factory Default +1.00
[Pro
c
e
ss
S
c
ale
]
Parameter Type Read & Write Minimum –327.68
This value sets the scaling multiplier for [Process Par].
The displayed value will be:
[Process Par] actual value
[Process Scale]
value
Displayed Value
Units Numeric Maximum +327.67
[Pro
c
e
ss
Tx
t 1
-
8]
Parameter #(s) 129-136 Factory Default ‘‘?’’
[Pro
c
e
ss
Tx
t 1
-
8]
Parameter Type Read & Write
These parameters set the ‘‘User Units” description for
the value determined by [Process Par] and [Process
Scale]. This text is displayed on Line 1 of the HIM.
Units ASCII Text
Character
The maximum value that can be displayed is 99,999.99. If this value is exceeded a
character string of asterisks (
*******
) will appear on the display.