Chapter 5 –Programming
5-15
Advanced Set Up Group (cont.)
[Ba
s
e
V
ol
t
a
g
e
]
Parameter # 18 Factory Default Max. Drive Rated Volts
[Ba
s
e
V
ol
t
a
g
e
]
Parameter Type Read & Write Minimum 25% of Max. Drive Rated Volts
This value should be set to the motor nameplate Rated
Voltage.
Units 1 Volt Maximum 100% of Max. Drive Rated Volts
[Base Voltage]
[Base Frequency]
Figure 5.6 Standard Volts-per-Hz Pattern
Motor Rated '
a
[Maximum Voltage]
[Maximum Frequency]
b
y
Motor Rated
0 –
0
Voltage
Frequency
[Brea
k F
re
qu
en
c
y
]
Parameter # 49 Factory Default 0 Hz
[Brea
k F
re
qu
en
c
y
]
Parameter Type Read & Write Minimum 0 Hz
This parameter sets a midpoint frequency on a custom
Volts-per-Hz curve. Combined with [Break Voltage], this
value determines the Volts-per-Hz ratio between 0 and
[Break Frequency]. Note: [DC Boost Select] must be
set to ‘‘Break Point” for this parameter to be active.
Units 1 Hz Maximum 120 Hz