Chapter 5 –Programming
5-7
Metering Group (cont.)
[
D
r
iv
e
Te
m
p
]
Parameter # 70 Factory Default None
[
D
r
iv
e
Te
m
p
]
Parameter Type Read Only Minimum 0
This parameter displays the drive internal temperature. Units 1_C Maximum Not Applicable
[La
st F
a
u
l
t]
Parameter # 4 Factory Default None
[La
st F
a
u
l
t]
Parameter Type Read Only Minimum 0
This parameter displays the fault code for the present drive
fault. If there is no active fault, the value will be zero.
Units Numeric Maximum Max. Fault Number
[%
O
ut
p
ut
Po
w
er
]
Parameter # 3 Factory Default None
[%
O
ut
p
ut
Po
w
er
]
Parameter Type Read Only Minimum 0 %
This parameter displays the percent of drive rated output
power.
Units 1 % Maximum 200% Drive Rated
Power
[%
O
ut
p
ut Cu
rr
]
Parameter # 2 Factory Default None
[%
O
ut
p
ut Cu
rr
]
Parameter Type Read Only Minimum 0 %
This parameter displays the percent of drive rated output
current.
Units 1 % Maximum 200% of Rated Drive
Output Current