Chapter 5 –Programming
5-6
Metering Group (cont.)
ut
ut F
q]
Parameter # 66 Factory Default None
ut
ut F
q]
Parameter Type Read Only Minimum – [Maximum Freq]
This parameter displays the output frequency present at
TB1, terminals T1, T2 & T3 (U, V & W).
Units 0.01 Hz Maximum + [Maximum Freq]
F
q C
mm
]
Parameter # 65 Factory Default 0.00 Hz
F
q C
mm
]
Parameter Type Read Only Minimum 0.00 Hz
This parameter displays the frequency that the drive is
commanded to output. This command may come from any
one of the frequency sources selected by [Freq Select 1],
[Freq Select 2] or [Preset Freq 1-7] the preset speeds 1-7
as determined by the inputs to SW1, SW2, and SW3 at
TB2.
Units 0.01 Hz Maximum +400.00 Hz
Hz]
Parameter # 42 Factory Default None
Hz]
Parameter Type Read Only Minimum 0.00 Hz
This parameter displays the frequency reference
commanded by the MOP function through serial
communication. This value is displayed regardless of
whether or not this is the active frequency command.
Units 0.01 Hz Maximum 400.00 Hz