Rockwell Automation Publication 750-PM001J-EN-P - October 2014 221
Port 10 and Port 11 Parameters Chapter 4
Converter (Port 11) Common
Parameters
Converter Common parameters apply only to PowerFlex 755 AC Input Frame 8
and larger drives.
File
Group
No. Display Name
Full Name
Description
Values
Read-Write
Data Type
CONVERTER COMMON
System Ratings
1 Sys Rated Amps
System Rated Amps
Displays the continuous current rating of the converter system.
Units:
Default:
Min/Max:
Amps
0.00
0.00 / 5000.00
RO Real
2 Sys Rated Volts
System Volts
Input voltage class (400, 480, 600, 690, etc) of the converter system.
Units:
Default:
Min/Max:
V AC
0.00
0.00 / 690.00
RO Real
3
4
5
C1 Rated Amps
C2 Rated Amps
C3 Rated Amps
Converter n Rated Amps
Continuous current rating of converter n. Used with AC Input drives.
Units:
Default:
Min/Max:
Amps
0.00
0.00 / 3000.00
RO Real
755 (8+)
755 (8+)
755 (8+)
755 (8+)
755 (8+)
File
Group
No. Display Name
Full Name
Description
Values
Read-Write
Data Type
CONVERTER COMMON
Status
10 Online Status
Online Status
RO 16-bit
Integer
Indicates whether the converter has successfully established fiber optic communications with the main control board.
12 Fault Status
Fault Status
RO 16-bit
Integer
Indicates whether the converter has a fault condition. See [Cn Fault Statusn] to view which fault conditions currently exist for converter n.
13 Alarm Status
Alarm Status
RO 16-bit
Integer
Indicates whether the converter has an alarm condition. See [Cn Alarm Statusn] to view which alarms currently exist for converter n.
755 (8+)
Options
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Converter 2
Converter 1
Default0000000000000000
Bit 1514131211109876543210
0 = Not Active
1 = Active
755 (8+)
Options
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Converter 2
Converter 1
Default0000000000000000
Bit 1514131211109876543210
0 = No Fault
1 = Fault
755 (8+)
Options
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Converter 2
Converter 1
Default0000000000000000
Bit 1514131211109876543210
0 = No Alarm
1 = Alarm