Rockwell-automation 21G PowerFlex 750-Series AC Drives Programming Man Manual de usuario Pagina 511

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 544
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 510
Rockwell Automation Publication 750-PM001J-EN-P - October 2014 511
Integrated Motion on EtherNet/IP Appendix E
Not every combination of P6 [Fdbk0 Device Sel] and P36 [Fdbk1 Device Sel]
are allowed. The following table shows the allowed and forbidden combinations.
Forbidden selections lead to a Configuration Conflict (Type 2 Alarm): Bit 20
“FB0FB1 Cflct” of P1 [Module Status] is set.
P6 [Fdbk0 Device Sel]
None
EnDat SC
Hiperface SC
BiSS SC
SSI SC
EnDat FD ChX
EnDat FD ChY
BiSS FD ChX
BiSS FD ChY
SSI FD ChX
SSI FD ChY
SinCos only
Incmtl A B Z
Incmtl SC
LinTempo ChX
LinTempo ChY
LinStahl ChX
LinStahl ChY
Lin SSI ChX
Lin SSI ChY
Hall Sensor
P36 [Fdbk1 Device Sel]
None ❍❍❍❍❍❍❍❍❍❍❍❍❍❍❍❍❍❍❍❍
EnDat SC ●●●●●❍●❍●❍●●●❍●❍
Hiperface SC ●●●●●❍●❍●●●❍●❍
BiSS SC ●●●●●●❍❍●❍●●❍●●❍
SSI SC ●●●●●❍●❍●●●❍●❍●❍
EnDat FD ChX ●●●●● ●❍●❍❍●❍●❍●❍
EnDat FD ChY ❍❍❍❍❍ ❍❍❍❍
BiSS FD ChX ❍●●●●●❍● ●❍❍❍●❍●❍●❍
BiSS FD ChY ❍❍❍❍❍❍ ❍❍❍❍
SSI FD ChX ❍●●●●●❍●❍● ❍❍❍●❍●❍●❍
SSI FD ChY ❍❍❍❍❍❍ ❍❍❍❍
SinCos only ●●●●❍❍❍❍❍❍❍❍❍❍❍❍
Incmtl A B Z ❍❍❍❍❍❍❍❍❍❍❍❍❍❍❍❍❍❍❍
Incmtl SC ●●●●❍❍❍❍❍❍❍❍❍❍❍❍
LinTempo ChX ❍●●●●●❍●❍●❍●●●●●●
LinTempo ChY ❍❍❍❍❍❍❍❍❍●●●●●●
LinStahl ChX ❍●●●●●❍●❍●❍●●●●●●
LinStahl ChY ❍❍❍❍❍❍❍❍❍●●●●●●
Lin SSI ChX ●●●●●❍●●●●●●●
Lin SSI ChY ❍❍❍❍❍❍❍❍❍●●●●●●
Hall Sensor
Forbidden Combinations
Allowed Combinations
Not Implemented
Vista de pagina 510
1 2 ... 506 507 508 509 510 511 512 513 514 515 516 ... 543 544

Comentarios a estos manuales