Rockwell Automation Publication 750-PM001J-EN-P - October 2014 73
Drive Port 0 Parameters Chapter 3
FEEDBACK & I/O
Digin Functions
176 DI HOA Start
Digital Input Hand-Off-Auto Start
A start for a hand-off-auto configuration. A delay filter allows the start and stop signals
to come from the same circuit.
Default:
Min/Max:
0.00
0.00 / 159999.15
RW 32-bit
Integer
177 DI MOP Inc
Digital Input Motor Operated Potentiometer Increment
Assigns a digital input used to increment the MOP speed reference.
Default:
Min/Max:
0.00
0.00 / 159999.15
RW 32-bit
Integer
178 DI MOP Dec
Digital Input Motor Operated Potentiometer Decrement
Assigns a digital input used to decrement the MOP speed reference.
Default:
Min/Max:
0.00
0.00 / 159999.15
RW 32-bit
Integer
179 DI Accel 2
Digital Input Acceleration 2
Assigns a digital input used to activate P536 [Accel Time 2].
Default:
Min/Max:
0.00
0.00 / 159999.15
RW 32-bit
Integer
180 DI Decel 2
Digital Input Deceleration 2
Assigns a digital input used to activate P538 [Decel Time 2].
Default:
Min/Max:
0.00
0.00 / 159999.15
RW 32-bit
Integer
181
182
DI SpTqPs Sel 0
DI SpTqPs Sel 1
Digital Input Speed Torque Position Select n
Assigns digital inputs used to select between speed, torque, and position modes.
Refer to position B5 in the block diagram on page 423
for details.
Default:
Min/Max:
0.00
0.00 / 159999.15
RW 32-bit
Integer
185 DI Stop Mode B
Digital Input Stop Mode B
Assigns a digital input used to activate P371 [Stop Mode B].
Default:
Min/Max:
0.00
0.00 / 159999.15
RW 32-bit
Integer
186 DI BusReg Mode B
Digital Input Bus Regulation Mode B
Assigns a digital input used to activate P373 [Bus Reg Mode B].
Default:
Min/Max:
0.00
0.00 / 159999.15
RW 32-bit
Integer
187 DI PwrLoss ModeB
Digital Input Power Loss Mode B
Assigns a digital input used to activate P453 [Pwr Loss Mode B].
Default:
Min/Max:
0.00
0.00 / 159999.15
RW 32-bit
Integer
188 DI Pwr Loss
Digital Input Power Loss
Assigns a digital input used to force a power loss condition.
Default:
Min/Max:
0.00
0.00 / 159999.15
RW 32-bit
Integer
189 DI Precharge
Digital Input Precharge
Assigns a digital input used to force the drive into precharge (often used in Common DC
input applications). A low signal forces the drive into precharge.
Default:
Min/Max:
0.00
0.00 / 159999.15
RW 32-bit
Integer
190 DI Prchrg Seal
Digital Input Precharge Seal
Assigns a digital input used to force a unique fault when an external precharge circuit
opens.
Default:
Min/Max:
0.00
0.00 / 159999.15
RW 32-bit
Integer
File
Group
No. Display Name
Full Name
Description
Values
Read-Write
Data Type
Auto Reference Source
(Parameter)
Input Status (1 = Input Actuated)
DI Speed Sel 0 DI Speed Sel 1
P309 0 0
P310 0 1
P311 1 0
P312 1 1