272 Rockwell Automation Publication 193-UM015B-EN-P - June 2014
Chapter 7 Metering and Diagnostics
17 Line to Line Under-Voltage condition detected
18 Line to Line Over-Voltage condition detected
19 Phase to phase voltage imbalance detected
20 The unit detects the supply voltage phases are rotated
21 Line voltage frequency is below the warning level
22 Line voltage frequency has exceeded warning level
33 Total Real Power (kW)is below warning level
34 Total Real Power (kW)has exceeded warning level
35 Under Reactive Power Consumed (+kVAR) condition detected
36 Over Reactive Power Consumed (+kVAR) condition detected
37 Under Reactive Power Generated (-kVAR) condition detected
38 Over Reactive Power Generated (-kVAR) condition detected
39 Total Apparent Power (kVA) is below warning level
40 Total Apparent Power (kVA) exceeded warning level
41 Under Total Power Factor Lagging (-PF) condition detected
42 Over Total Power Factor Lagging (-PF) condition detected
43 Under Total Power Factor Leading (+PF) condition detected
44 Over Total Power Factor Leading (+PF) condition detected
50 PTC input indicates that the motor stator windings overheated
51 DeviceLogix defined warning was generated
56 Invalid parameter config. See parameters 38-39 for details
58 DeviceLogix Feedback Timeout Trip was detected
60 Number of Starts Warning Level Exceeded
61 Operating Hours Warning Level Exceeded
65 Input Channel 00 on Analog Module 1 exceeded its Warning Level
66 Input Channel 01 on Analog Module 1 exceeded its Warning Level
67 Input Channel 02 on Analog Module 1 exceeded its Warning Level
68 Input Channel 00 on Analog Module 2 exceeded its Warning Level
69 Input Channel 01 on Analog Module 2 exceeded its Warning Level
70 Input Channel 02 on Analog Module 2 exceeded its Warning Level
71 Input Channel 00 on Analog Module 3 exceeded its Warning Level
72 Input Channel 01 on Analog Module 3 exceeded its Warning Level
73 Input Channel 02 on Analog Module 3 exceeded its Warning Level
74 Input Channel 00 on Analog Module 4 exceeded its Warning Level
75 Input Channel 01 on Analog Module 4 exceeded its Warning Level
76 Input Channel 02 on Analog Module 4 exceeded its Warning Level
81 Digital Expansion Module 1 is not operating properly
82 Digital Expansion Module 2 is not operating properly
83 Digital Expansion Module 3 is not operating properly
84 Digital Expansion Module 4 is not operating properly
85 Analog Expansion Module 1 is not operating properly
86 Analog Expansion Module 2 is not operating properly
87 Analog Expansion Module 3 is not operating properly
Warning History Code Description
Comentarios a estos manuales