Editing ProgramsOn Line
Chapter 5
5-14
3. Key in an initial sequence number (the number for the first sequence
number), a comma, and an incremental value for the control to add to
each new sequence number. The format to this command is
RENUM: initial-sequence-number, incremental -value
For example
RENUM:5,10
would make the first sequence number 5, the next 15, 25, 35....
Important: You must enter both the initial sequence number and the
incremental value as integer values. If you use a decimal point, the control
issues the error message “ILLEGAL VALUE”.
If no initial sequence number or no incremental value is given or
both are not entered, the control uses default values of one.
4. Select the blocks to renumber by using one of the two choices:
(softkey level 4)
ALL ONLY
N
Ifyo u want to: Then press:
assignsequence numbersor toreassignsequence numbersto
all blocksfromthe beginning ofthepart program
{ALL} softkey
assignnew sequence numbersto only theblocksthatalready
havesequencenumbers
{ONLY N}
softkey
ATTENTION: When the control performs a renumber
operation, features in the part program that reference a specific
block number may no longer be referencing the correct block.
For example, a paramacro GOTO 10 command may not call t he
correct block after the renumber operation. When a renumber
operations is performed, you must manually go through the
program to make sure that these block references are correct.