Error and System Messages
Appendix B
B-31
Message Description
O
OBJECTNOT FO UND IN PROGRAM The objectyouare searchingfor in thesearchmonitor utilitydoes notexistin thecurrent
module,or does notexistintheprograminthedirectionyouare searching.
OCI ETHERNET CARD NOT INSTALLED AnOCIdual--processsystemhas a standardCRT installed. The OCI Ethernetcard has not
been installed. This mayhappen if a dual--process OCI executive isloadedintoa non--OCI
system.
OCI SYSTEM ERROR VRTXerror. ContactAllen BradleySupport.
OCI PROCESSING TASKOVERLAP The amountof timeto processa new OCI requestis takinglongerthan expected. This isan
informational warning only. Itisnotcriticalto theCNC.
OCI WATCH LIST TASKOVERLAP T his messageindicates thatthe watchlist taskwasnotrunning to completion in the AMPed
allotted amountoftime. This typicallyoccurswhen a large taskis requestedby an OCI station
and theCNC takes longerthanexpectedtocomplete.
ODS & 9/SERIES REVISIONS DIFFER The version ofAMPorPAL on theperipheraldevice does notmatch the control version.
ODS RUNG MONITORACTIVE The online PALsearch monitorutility can notbeaccessed. The online PAL searchmonitor
utilityrequirestheofflineODSPALsearchmonitor utilityto notbe running.
OFFSET EXCEEDS MAX CHANGE You have attempted tomodifyanoffsettable byanamountthatis largerthanthe allowable
changetoan offset table. Referto yourAMPreference manual for detailson Maximumwear
and geometryoffsetchange.
OFFSET EXCEEDS MAX V ALUE You have attempted to modifyan offsettableby enteringan offset amountthatis larger thanthe
allowable maximumoffsetselectedin AMP. Referto yourAMPreferencemanual fordetailson
Maximumoffsettablevalues.
OFFSET MOTION PENDING ON CYCLESTART Afterchangingthe active offsetthismessageidentifies thatthe controlwill movetheaxis tothe
new offsetlocation the nexttime cycle start is pressed (this may or may not occur on a
non--motionblock depending on theAMPoffsetconfiguration).
OFFSET TABLE(S)CORRUPT/CLEARED A bad offsettable checksum value was detected by the control during PTO.
ONLYONE DEPTH PROBE PER SERVO BOARD The 9/Seriesservo card firmwareonly supportsone adaptivedepth probeoneachservo card.
Ifyour systemrequires morethan one adaptive depthprobe theymustbeattached todifferent
servocards(9/230 and 9/440controlscanonly have one adaptivedepth probe). AMPmustbe
configured toindicate whichporttheadaptive depthprobe is attached to.
ONLYONE M19 ALLOWED PER BLOCK For systemconfigured with multiple spindles, only one spindle orient M-code (M19) is allowed
perblock.
ONLYREQUEST THE DUAL MASTER FOR JOGS Anattemptwas made tojogaslaveaxis;you can jog a slaveaxisonly when themasteraxis is
parked.
OPTION NOT INSTALLED An attemptwas madetoprogram an optionalfeaturethathasnotbeen purchased from
Allen-Bradley.
OPTION NOT INSTALLED (PAL DISPLAY PAGE) ThePALdisplay page optionis not installedon your control.
OPTIONALFEATUREISNOT PROVIDED An attemptwas made toprogram an optionalfeature thathas not been purchasedfrom
Allen-Bradley.
OPTIONAL RAM SIMM BAD/MISSING The control hasdiscoveredtheRAM SIMMsfortheextendedstorageoptionare either
damagedormissing. T he RAM SIMMs mustbe installedorreplaced. ContactyourAllen
Bradleysales representative forassistance.
OTHERPROCESS G CODECONFLICT On a dual processing system,oneprocesshasa conflicting G code active when you attempted
toactivatea G26 depthprobe cycle. For example, processone executesa G26 while process
twohas an axis in feedto hard stopwhich is on thesame servocard as thedepth probe.
OVER SPEED A servomotor is turningatan RPM thatis greaterthan themaximumRPM allowed forthat
servo as defined in AMP by the system installer . For digital spindles this error can result from
maximumRPMgear range1beingsethigher thanyourAMPedallowed MaximumMotor
Speed.