Introduction to Programming
Chapter 10
10-19
Later sections describe these words in more detail, including variations in
their meanings when they are associated with certain G codes. All words
described in this manual assume the formats and addresses in the following
table have not been changed by your system installer.
Important: The formats in this table indicate the maximum number of
digits to the left and right of the decimal point for each word. In many
cases, they are not valid together since the control allows a maximum of 8
total digits. See your system installer’s manual for specific formats.
Table 10.B
Word Formats and Descriptions
Address Valid Range
inch
Valid Range
metric
Function
A 8.6
3.3
8.5
3.3
RotaryaxisaboutX (AMPassigned)
AngleinQuickPathPlus programming
B 3.0 3.0 Secondmiscellaneousfunction(AMPassigned)
C 8.6
8.6
8.5
8.5
RotaryaxisaboutZ (AMP assigned)
Chamferlengthin QuickPath Plus programming
D 8.6
3.0
8.5
3.0
Fixed cycle parameter
Number of dresses in fixed cycle
E 2.6
8.6
3.7
8.5
Thread lead
Reciprocation Feedrate
F 8.6 8.5 Feedratefunction(F word)
G 2.1 2.1 Preparatoryfunction(G word)
I 8.6
8.6
8.6
8.6
8.5
8.5
8.5
8.5
Xarccenterin circularinterpolation
Xleadinhelicalinterpolation
Parameterin fixed cycles (AMPassi gned)
Exitmovevectorin cuttercompensation
J 8.6
8.6
8.5
8.5
Parameterin fixed cycles (AMPassi gned)
Exitmovevectorin cuttercompensation
K 8.6
8.6
8.6
8.5
8.5
8.5
Z arccenterincircular interpolation
Parameterin fixed cycles (AMPassi gned)
Exitmovevectorin cuttercompensation
L 3.0 3.0 Numberof repetitions
M 3.0 3.0 Mi scellaneous function
N 5.0 5.0 Sequencenumber
O 5.0 5.0 Programname
P 5.0
5.0
5.3
5.0
5.0
5.3
Subprogram/paramacroprogramname
Dressingprogram name
Lengthof dwell in G 04 and fixedcycles
Q 8.6 8.5 Parameter in fixed cycles
R 8.6
8.6
8.5
8.5
Arcradius
QuickPath Plus radiusdesignation