Error and System Messages
Appendix B
B-11
Message Description
DEPTH PROBE TRAVEL LIMIT The adaptivedepth probehasmoved toitsAMPedtravellimit. Note thevalue enteredinAMP
istheadaptivedepthprobe deflectionfromthe PALdeterminedprobezero point. Itmay notbe
theactual total probe deflection.
DEPTH PROBE NOT SUPPORTED A depthprobe axis has been AMPed on an axisl ocated on a servocard or a 9/230that does
notsupporttheadaptive depthfeature. (analog servorev < rev0.10or 3 axis 9/2609/290
digitalservo cards)
DESKEW OPTION NOT INSTALLED IftheAMPed name specifying thedeskew slaveservo isnotzero,orthe AMPedname
specifyingthedeskew master servoisnot zero,and the optionflagfordeskewis zero,then the
system is held in E-Stop.
DEVICE ALREADY OPENED An attempt was madetoopen a device fordownload or upload fromportsAor B when the
devicewas already opened.
DEVICE NOT OPENED YET T he ready signal was notreceived when attempting tosenddata toor communicate witha
peripheraldevice connected tocommunication portsA orB.
DIAMETER AXISMISCONFIGURED An invalidaxishas been configuredas thediameter axis.
DIRECTO RYCHANGEDTO MAINDIRECTORY When a passwordis enteredthatdoesnothave accessto theprotectablepart program
directoryand the protectable part programdirectoryis currently selected,thecontrolchanges
the selected directory to the main directory.
DISP SELECT NOT ALLOWED You can not usethedisplayselectfunctions while the online PALsearch monitorutilityis active.
Leavethesearchmonitor utilitybeforeyoutrytoselecta display.
DIVIDE BY ZERO ERROR Asystemsoftwareerror hasoccurred. Consult Allen-Bradley customersupport services.
(DO) NUMBER ALREADY USED When executinga program,an attemptwasmadeto activate a DO loop thathas thesame loop
identifier(DO1,2, or 3)asan already activeloop in the program. Providedtheyarenotnested
loops,the sameloop identifiercan be used morethanonce in a program.
(DO)RANGESINTERSECT DO loops are improperlynested. A DO loop thatis nestedwithin anotherDOloopdoesnot
haveanENDcommandbefore theoriginalDO loopENDoccurs.
DRESSCANCEL DEFERREDTO G40 Thein--processdresser cannot be canceled(made inactive)while dresser/wheel radius
compensationi s active. Ifan attemptto cancelthein--processdresseris made,thecontrolwill
postponethe requestuntil dresser/wheelradius compensation iscanceledwith a G40 (notethat
M02,M30,andM99can also cancelcompensation).
DRESSER AXIS NOT ALLOWED Anattemptwasmadeto programthe dresseraxis when the overthe wheel dresserfeaturehas
been activatedthrough PAL. Youcannot programthe dresseraxis when theover thewheel
dresserfeature isactive.
DRESSER FLANGE LIMIT REACHED W hile dressing thegrindingwheel the wheel size reachedthe enteredflange limit. You should
stopdressing thewheel before damagetothe wheel flange occurs.
DRESSER MINIMUM LIMIT REACHED The currentdressingoperation would dressthe grinding wheel below theminimumwheel
diameteras specified on the dresserstatusscreen. This dressingoperation will notbe
performed.
DRESSER MISCONFIGURED One oftheAMPparametersfor thedresseraxishas notbeen configured properly. Eitherthe
dresser axis, the vertical axis, or some other axis name is not a valid axis in the system. You
mustre-configure your AMP. Refer toyourAMPmanual fordetails.
DRESSER MIS-POSITIONED Wheel re-enablewasrequestedwithIPDactive and wheel is more than4 inch-programming
counts(hard-codeamount)away fromits previouslyactiveabsolute position. Wheel dressing
doesnotstart.
DRESSER NOT INITIALIZED T his errorisgenerated ifan attemptis madetoactivatethe in--process dresserbefore the
dresserhas been initializedthroughawheelcalibration operation.
DRESSER NOT/MISCONFIGURED The grinder over-the-wheel dresserfeature issuesthismessagewhen a wheel is initializedand
thedresserparameters in AMPhave been misconfigured. This messageis issued when the
dresseraxis,dresservertical axis,ordresserotheraxishasnotbeen selected,or hasbeen
AMPed tohave commonaxes,orhasbeen AMPedtobe a non-existentaxisname.