Appendix
B
B-1
Error and System Messages
This appendix serves as a guide to error and system messages that can
occur during programming and operation of the 9/Series control. We listed
the messages in alphabetical order along with a brief description.
Important: To display both active and inactive messages, press the
{ERROR MESAGE} softkey found on softkey level 1. For details, see
chapter 2.
Important: This appendix covers only error and system messages.
PAL-generated operator messages generally appear on lines 21 and 22 of
the CRT and should be described in documentation prepared by the
machine tool builder.
Message Description
Symbols
(+) 15V SUPPLY FAILURE + 15 Vdcisnot available atthe main processor board. Checkthe wiresfromthemain power
supplyand connectorCN07 onthemain processorboard.
(--) 15V SUPPLY FAILURE -- 15 Vdc is notavailable at themain processorboard. Check the wiresfromthemain power
supplyand connectorCN07 onthemain processorboard.
(+) OVERTRAVEL PROGRAM ERROR Ifaxis motioncontinuesalongtheprogrammedpath,the indicatedaxis will reachorexceed the
positive software overtravel limit(runtime error).
(--) OVERTRAVEL PROGRAM ERROR Ifaxis motioncontinuesalongtheprogrammedpath,the indicatedaxiswill reach orexceedthe
negativesoftwareovertravel limit (runtime error).
(+) OVERTRVLPRGRAM ERROR: T he end-point ofthe commandedmove will causetheindicatedaxisto reachor exceed the
positive software overtravel limit (pre-execution error).
(--) OVERTRVL PRGRAM ERROR: The end-point ofthe commandedmove will causethe indicatedaxis to reachor exceed the
negativesoftware overtravel limit(pre-executionerror).
+/-- SIGN ERROR A + or -- sign was foundoutof placewhenanumericvalue wasbeingdecoded. Checkthe
active programblock forprogrammingformat errors.
1
1394 AXIS MODULE MISMAT CH At power turnon the systemidentified an axis module in the 1394 rack thatis misconfigured in
AMP. Ifanextra axis moduleispresentinthe1394 rackitshould eitherbe fully configured or
notconfiguredatall in AMPevenifthataxis module isnotused or detached.
1394 RINGCOMMUNICATIONSERROR Atpower up the internal communicationsring which runs throughthefrontofthe 1394 system
and drivemodules was eithernot connected,a device on theringexperienced a hardware
failure,oradeviceon the ring wasdiscoveredto be misconfigured once a commandwas sentto
thedevice. Makesure all axismodulesand the end terminator areproperlyconnectedto
complete the communicationring.
1746 RACKCARDS MISMAT CH The I/O configurationfor the1746I/O rack thatwas downloaded fromODS,orresidesin the
PALPROMs,contradictswhatis actuallyin therack(devicesmustmatchslot-for-slot).
1771 RACKCARDS MISMAT CH The I/O configurationfor the1771I/O rack thatwas downloaded fromODS,orresidesin the
PALPROMs,contradictswhatis actuallyin therack(devicesmustmatchslot-for-slot).