Error and System Messages
Appendix B
B-3
Message Description
AMP WASMODIFIED BY PATCH AMP UTILITY This messagealways appearsafterchangeshave been made toAMPusingthe patchAMP
utility. Itspurpose is toremind theuserthatthecurrentAMPhas not been verifiedby a
cross-referencecheck normallyperformed byODS. Itis meantas a safetywarning.
AMPED HOLDING OR DETECT TRQ OUT OF RANGE This message isdisplayed when youhaveentered a valueinAMPforeither theholding torque
orthedetectiontorque,for thefeedto hardstop feature,thatishigher than thevalue enteredfor
theservosavailablepeak torque. Youmustchangeyour AMPvalues.
ANALOG SERVO VOLTAGE F AI LURE A+15V tothe servocards hasfailed.
ANGLEWORD NOT ALLOWED Ananglewordwas programmedin a QPP blockwhereit is notallowed, forexample,
programming an angle word in a circularQPPblock.
ANGLED WHEEL AXES, JOG ONE AT A TIME W hile in the angled wheel grinding modeyoucan not jog morethan one axisinthe angled
wheel plane atanyone time.
ANGLED WHEEL CONFIG ERROR The angled-wheel grinderAMPdownloadedtothe control isnotconfiguredcorrectly. Makesure
all necessaryangled-wheelparametersare configured correctlyand re-download AMPtothe
control.
ANGLED WHEEL NOT CONFIGURED Youhaveattempted toprogram an angled wheel grindermodefunctionand the angled wheel
featurehas not been correctlyconfiguredfor yoursystem. The angled wheel feature mustbe
configured in AMPand is a purchasedoption foryour 9/Seriescontrol.
ARCTANSYNT AXERROR An attemptwas madetocalculateor executea paramacroblockthatcalculatesthe arctangent
ofan invalid or improperlyenterednumber.
ARITHMETIC OVERFLOW ERROR An internal math errorhas occurred;contactAllen-Bradleycustomersupportservice.
ARITHMETICUNDERFLOW ERROR An internalmath errorhas occurred;contactAllen-Bradleycustomersupportservice.
AUX FB NOT ALLOWED WITH DEPTH PROBE Your AMPfile hasadepthprobe configuredfor an axisthatalsois configuredto use an optional
feedbackdevice. A depthprobecan not be configured touse any feedbackdevice otherthen
itsdepth probeforthatdepth probe axis. Ifa secondfeedbackdeviceis used itisconfiguredin
AMPas a separate logical axis.
AUXILIARYFEEDBACKDISCONNECTED The digital servomodule providesthe capabilitytousetwo differentfeedback encoderswithone
servo(in thecasewhere twoencodersare used,the auxiliaryencoder is usedfortheposition
feedback). Ifthe servoprocessordetectsthatthe auxiliaryencoder hasbeen disconnected,this
message isdisplayed.
AUXILIARYFEEDBACKQUADRATURE FAULT The digitalservomoduleprovides thecapabilitytouse twodifferentfeedbackencoderswithone
servo(in thecasewhere twoencodersare used,the auxiliaryencoder is usedfortheposition
feedback). Ifthe servoprocessordetectsa quadraturefaulton theauxiliary encoder,this
message isdisplayed.
AUXILIARYSPINDLE 2 NOT CONFIGURED For auxspindle2 to be programmable,it mustbe configuredin AMP;a decode error.
AUXILIARYSPINDLE 3 NOT AVAILABLE AMPconfiguration error;auxspindle3canbe configuredonlyon a 9/290.
AUXILIARYSPINDLE 3 NOT CONFIGURED For auxspindle3 to be programmable,it mustbe configuredin AMP;a decode error.
AXES COLLISION Twoprocesseshave collided. Interference checkinghas stoppedall motion.
AXES CONFIGURED ON INACTIVE PROCESS AnAMPwasloaded thatcontains an axis thatwas configuredforaninactive process. Setthe
processaxis in AMPtoa processthathas been configured.
AXES DATAMISSING Expectedaxis datai s missinginaprogramblock.
AXISAMPED AS NON-SCALING AXIS Theuserattemptedto scaleanaxisthatwas AMPedas non-scaleable.
AXISASSIGNED TO PAL AXIS MOVER The user attempted tomove theaxisconfiguredas the PALaxismoveraxis by somemeans
otherthan PAL.
AXISDISPLAY DISABLED BY PAL The positiondisplay fora selectedaxishas been turnedoffusing the$NODPflag.
AXISIN PLANE DOES NOT EXIST Atleastone of theaxesassigned toa plane thatwasdefinedin AMPdoes not exist. An
exampleof when thiserror would occuris if an axiswas renamed in AMP,but thatnew name
wasnotenteredintothe AMPplane definition. Anotherexamplewouldbeifan unfitted axis
wasassignedto thatplane.