Error and System Messages
Appendix B
B-2
Message Description
2
2MB RAM IS BAD/MISSING The controlhas discoveredthe RAMSIMMs forthe twomegabyteextended storage optionare
eitherdamaged or missing. The RAMSIMMsmustbe installedorreplaced. ContactyourAllen
Bradleysales representative forassistance.
9
9/SERIES LA THE - CANNOT USE MILL AMP T he control waspoweredup with a lathe software option chipinstalled, when theAMPfilethat
wasdownloadedwasconfigured fora mill.
9/SERIESMILL -CANNOT USELATHEAMP T he control waspoweredup with a mill softwareoption chipinstalled,when the AMPfile that
wasdownloadedwasconfigured fora lathe.
7300
7300 NAMESTABLEISCORRUPTED 7300programnamedoesn’tmatchcorrespondingnamein cross-reference table.
7300 PATTERN NAMETOO LONG More than 5 digitshave been used in thepatternname.
A
A RETRACE BUFFER WASDELETED The controlrequiredone (or more)of theblockretracebuffers toperforma necessaryblock
look-aheadoperation (refertoblock look-aheadin the user’smanual). When thisoccurs,less
blockretraceoperationscanbe performedthan AMPis configuredto allow. Ifthiserroroccurs,
toimprove control efficiency, itisrecommendedthatthenumber ofallowable block retrace
blockssetin AMPbe lowered oraddadditionalRAM toyousystem.
ABS POSITION NOT INITIALIZED This messageindicatesthataxeswith absoluteencodershave notbeen homed. These axes
requirean initial homing operationto establish the absoluteposition.
ABSOLUTE FEEDBACK FAILURE The controlhas detected a lossoffeedbackfromtheabsoluteencoder. The mostlikely cause
ofthis errorwould be a brokenordisconnectedwire. Axis homingmay be requiredafter the
errorconditioniscorrected.
ACC/DEC CONFIGURATION ERROR Anaxis configuration error wasdeterctedby thecontrolwhenmanualacc/decwasrequestedin
a programblock.
ACCUM.AND EXPECTED LIFE ARE0 Notoollife datawasentered forthe currenttoolselected by the toollife managementfeature.
Toollifemanagementwill be disabled forthistool.
ACTIVE GROUP CANNOT BE DELETED Anattemptwasmadeto deleteatoolgroup in the toollifemanagementfeaturethatcontains an
active toolcurrentlyin the toolholder.
ACTIVEOFFSET CANNOT CHANGE Anattemptwasmade toaltera tool offsetvalue ofatooloffset thatis currently the active tool
offseton the control. The activetooloffset isindicated with an * on thetooloffset table.
ACTIVETOOL CANNOT BE CHANGED An attemptwasmadeto edittooldata forthe currentlyacti ve tool. De-activate thetool before
editing.
ACTIVE TOOL CANNOT BE DELETED An attemptwasmadeto deletetooldata forthe currentlyactivetool. De-acti vate thetool before
editing.
ADAPTIVEFEED MIN LIMIT Thismessageindicatesyourare exceedingtheprogrammeddesired torque. The actualtorque
isgreaterthanthe desiredprogrammedtorque and theadaptivefeedaxis hasreachedthe
programmed minimumfeedlimit. Eitherraisetheprogrammeddesired torqueor lower the
minimumfeedlimit.
ADAPTIVEFEED PROGRAMMING ERROR E and Q mustboth be programmed in everyG25 block.
ALL DUAL AXES ARE PARKED An attempt was made,while using dual axes,to movethedual group when all the axesof that
groupwereparked.
AMPFILESIZEERROR The size ofthe AMPfile being downloaded isincorrect. T he file cannotbe downloaded.
AMP IN BACKUP DOES NOT MATCH AMP IN RAM T his messagealwaysappears after a successful AMPdownloadifthe downloaded fileis
differentfromthe one currently storedin backup memory. Itspurpose istoremind theuserto
copythe downloaded AMPinto backupmemoryaftertestingit.