Communications
Chapter 9
9-7
OUTPUT CODE
Select EIA (RS-244A) or ASCII (RS-358-B) as output codes for devices
with data lengths configured as 8 bit. The output code can not be
configured for data lengths configured as 7 bits and is displayed as N/A.
AUTOFILENAME
This parameter is valid only if you are inputting part programs to the
control from a tape reader (see DEVICE for details). Use this parameter
only if your tape contains more than one part program.
AUTO F ILENAME lets you automatically assign program names to all
programs or key in or read the filenames for each program individually as
they are copied into memory from a multiple program tape.
Setting Result
Yes The firstprogramon a multipleprogramtapemusthaveitsprogramname keyed in manually,or there
mustbe a programname as thefirstblock ofthefirstprogram. The controlautomaticallycreates
programnames forsuccessive programson thattape by incrementing the programname by one as
eachnewprogramis read. The controlignoresall program namesthatexistasthefirstblock ofthe
programforanyprogram readafter the firstprogramon tape (thoughthese blocksare stillcopiedinto
memory,they arenotused as theprogramname). The controlgeneratesanerrorif when reading
programnames intomemory,the controlneeds toincrementa program namethatisgreaterthan
99999.
Important: If the first programname is tobereadfrom tape (notmanually keyedin), thefirstblock
of the first program must contain a program name in one ofthe following formats:Oxxxxx (ASCII),
Nxxxxx or:xxxxxwhere xxxxx isanyvalid integer.
No The programnamefor each programon a multi-programtapemustbe entered fromthekeyboard or
locatedas thefirstblock ofeachprogram aftertheprogramstart code on thetape. Ifno programname
isfoundin the firstblock and no programname is keyedin,the controlgeneratesan error.
Important: If the programname is tobe read fromtape (notmanually keyedin),the firstblock of
the program must contain a program name in one ofthe following formats: Oxxxxx (ASCII),Nxxxxx or
:xxxxxwhere xxxxxisanyvalid integer.
STOP PRG END
This parameter is available only if you have selected a tape reader as your
device (see DEVICE for details). It determines if the tape reader is to stop
at the end of each program or continue reading until the end-of-tape code is