Parameter Descriptions
11-27
Specifies if Ref A speed reference is to be trimmed.
Scales the upper value of the Trim In Select (117) selection when
the source is an analog input. This parameter should be set in
conjunction with parameter 322 or 325.
Scales the lower value of the Trim In Select (117) selection when
the source is an analog input. This parameter should be set in
conjunction with parameter 323 or 326.
118 Trim Out Select
Range: See figure 11.9
Default: See figure 11.9
Access: 2 Path: Speed Command>Speed Trim
See also: 117, 119, 120
Figure 11.9 – Trim Out Select (118)
x
xx
0
xxxxxxxxxxxx
10 01234567891112131415
1
=Trimmed
0
=Not Trimmed
x =Reserved
Bit #
Factory Default Bit Values
Trim Ref A
Nibble 1Nibble 2Nibble 3Nibble 4
119 Trim Hi
Range: -/+ Maximum Speed [0.1 Hz]
Default: 60.0 Hz
Access: 2 Path: Speed Command>Speed Trim
See also: 82, 117, 322, 324
120 Trim Lo
Range: -/+ Maximum Speed [0.1 Hz]
Default: 0.0 Hz
Access: 2 Path: Speed Command>Speed Trim
See also: 117, 323, 325