11-66
SP600 AC Drive User Manual
Captures and displays Drive Alarm status at the time of the last
fault.
See parameter 211 for bit descriptions.
Captures and displays Drive Alarm status bit pattern at the time of
last fault.
See parameter 212 for bit descriptions.
229 Alarm 1 @ Fault
Range: See figure 11.27
Default: Read Only
Access: 1 Path: Utility>Diagnostics
See also: 211, 224-230
Figure 11.27 – Alarm 1 @ Fault (229)
000000
x
000
xxxxxx
10 01234567891112131415
1
=Condition True
0
=Condition False
x =Reserved
Bit #
Prechrg Actv
UnderVoltage
Power Loss
Str At PwrUp
Anlg in Loss
IntDBRes OH
Reserved
Drv OL Lvl 1
Drv OL LVl 2
Decel Inhibit
Waking
Nibble 1Nibble 2Nibble 3Nibble 4
230 Alarm 2 @ Fault
Range: See figure 11.28
Default: Read Only
Access: 1 Path: Utility>Diagnostics
See also: 211, 221-230
Figure 11.28 – Alarm 2 @ Fault (230)
00000000000
xx0x
10 01234567891112131415
1
=Condition True
0
=Condition False
x =Reserved
Bit #
DigIn CflctA
DigIn CflctB
DigIn CflctC
Bipolr Cflct
MtrTyp Cflct
NP Hz Cflct
MaxFrq Cflct
VHz NegSlope
IR Vlts Rang
FlxAmps Rang
SpdRef Cflct
Ixo Volt Rang
Sleep Config
Dig In Value
Nibble 1Nibble 2Nibble 3Nibble 4
UserSetCflct