Installing Control Wiring
7-3
Table 7.1 – Wiring Signal and Control I/O to the Terminal Block
No. Signal
Factory
Default Description
Related
Param.
Analog Inputs
1 Anlg Volts In 1 (–)
1
Isolated
2
, bipolar, differential, ±10
V, 11 bit & sign, 100k ohm input
impedance.
320 -
329
2 Anlg Volts In 1 (+)
3 Anlg Volts In 2 (–)
1
Isolated
3
, bipolar, differential, ±10
V, 11 bit & sign, 100k ohm input
impedance.
4 Anlg Volts In 2 (+)
5 Potentiometer
Common
For (+) and (–) 10 V pot
references.
Analog Output
6 Anlg Volts Out 1 (–) Output
Freq
1
Bipolar, differential, ±10 V, 11 bit
& sign, 2k ohm minimum load.
340 -
344
7 Anlg Volts Out 1 (+)
8 Anlg Current Out 1
(–)
1
4-20 mA, 11 bit & sign, 400 ohm
maximum load.
9 Anlg Current Out 1
(+)
10 Reserved
Digital Outputs
1
16
32