Rockwell-automation SP600 User Manual Version 3.0 Manual de usuario Pagina 77

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 274
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 76
Installing Control Wiring
7-5
26 24V Power Supply
Common (internal)
n/a Drive supplied power for logic
inputs. 150 mA maximum Load.
Digital Inputs
27 Digital In1 Stop/CF 24V AC/DC I/O Board
Opto isolated (250 V)
Low state: less than 5 V AC
High State: greater than 10 V AC
115 VAC I/O Board
4
Opto isolated (250 V)
Low state: less than 10 V AC
High State: greater than 100 V AC
361 -
366
28 Digital In2 Start
29 Digital In3 Function
Loss
30 Digital In4 Jog
31 Digital In5 Auto/
Manual
32 Digital In6 Speed
Select
1
These inputs/outputs are dependent on a number of parameters. See “Related
Parameters” column.
2
Differential Isolation - External source must be maintained at less than 160 V with
respect to PE. Input provides high common mode immunity.
3
Differential Isolation - External source must be less than 10 V with respect to PE.
4
Drive Model with 115V interface required. See figure 2.1.
Table 7.1 – Wiring Signal and Control I/O to the Terminal Block
No. Signal
Factory
Default Description
Related
Param.
1
16
32
Vista de pagina 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 273 274