12-18
SP600 AC Drive User Manual
UserSet1
Chksum
101
➁
The checksum read
from the user set does
not match the
checksum calculated.
Re-save user set.
UserSet2
Chksum
102
➁
UserSet3
Chksum
103
➁
Table 12.7 – Fault Descriptions and Corrective Actions (Continued)
Fault
No.
Type
Description Action
Table 12.8 – Fault Names Cross-Referenced by Fault Number
No.
1
Fault No.
1
Fault No.
1
Fault
2 Function Loss 38 Phase U to Grnd 80 AutoTune Aborted
3 Power Loss 39 Phase V to Grnd 81-86 Port 1-6 DPI Loss
4 UnderVoltage 40 Phase W to Grnd 100 Parameter Chksum
5 OverVoltage 41 Phase UV Short 101 UserSet1 Chksum
7 Motor Overload 42 Phase VW Short 102 UserSet2 Chksum
8 Heatsink OvrTemp 43 Phase UW Short 103 UserSet3 Chksum
9 Trnsistr OvrTemp 48 Params Defaulted 104 Pwr Brd Chksum1
12 HW OverCurrent 63 Shear Pin 105 Pwr Brd Chksum2
13 Ground Fault 64 Drive Overload 106 Incompat MCB-PB
24 Decel Inhibit 69 DB Resistance 107 Replaced MCB-PB
25 OverSpeed Limit 70 Power Unit 108 Anlg Cal Chksum
29 Analog In Loss 71-76 Port 1-6 Net Loss 120 I/O Board Mismatch
33 Auto Rstrt Tries 77 IR Volts Range 121 I/O Board Comm Loss
36 SW OverCurrent 78 FluxAmpsRef Rang 122 I/O Board Fail
79 Excessive Load
1
Fault numbers not listed are reserved for future use.