11-70
SP600 AC Drive User Manual
The output of the logic function control block resulting from the
combination of all port requests and masking functions. Each bit or
set of bits represent a command to the drive.
Present frequency reference scaled as a DPI reference for peer-to-
peer communications. The value shown is the output prior to the
accel/decel ramp and any corrections supplied by slip comp, PI, etc.
271 Drive Logic Rslt
Range: See figure 11.31
Default: Read Only
Access: 2 Path: Communication>Comm Control
See also:
Figure 11.31 – Drive Logic Rslt (271)
0110000101110000
10 01234567891112131415
1
=Condition Active
0
=Condition Inactive
x =Reserved
Bit #
Stop
Start
Jog
Clear Fault
Forward
Reverse
Local Contrl
Mop Inc
Accel 1
Accel 2
Decel 1
Decel 2
Spd Ref ID 0
(1)
Spd Ref ID 1
(1)
Spd Ref ID 2
(1)
MOP Dec
Nibble 1Nibble 2Nibble 3Nibble 4
Bits
(1)
Description14 13 12
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
No Command - Man. Mode
Ref A Auto
Preset 2 Auto
Preset 3 Auto
Preset 4 Auto
Preset 5 Auto
Preset 6 Auto
Preset 7 Auto
272 Drive Ref Rslt
Range: 0 to 32767 [1]
Default: Read Only
Access: 2 Path: Communication>Comm Control
See also: