Rockwell-automation SP600 User Manual Version 3.0 Manual de usuario Pagina 175

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 274
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 174
Parameter Descriptions
11-73
Parameter number whose value will be written from a network
communications device data table.
Parameters that can only be changed while the drive is stopped
cannot be used as Datalink inputs. Entering a parameter of this type
will disable the link.
Refer to the appropriate communications option board manual for
Datalink information.
Parameter number whose value will be written from a
communications device data table.
Parameters that can only be changed while the drive is stopped
cannot be used as Datalink inputs. Entering a parameter of this type
will disable the link.
Refer to the appropriate communications option board manual for
Datalink information.
300
301
Data In A1 - Link A Word 1
Data In A2 - Link A Word 2
Range: 0 to 387 [1]
Default: 0 (Disabled)
Access: 2 Path: Communication>Datalinks
See also:
Network
Network
Card
Data
P#
SP600
Data In
(parameter #)
Data Received by Drive from Network
302
303
Data In B1 - Link B Word 1
Data In B2 - Link B Word 2
Range: 0 to 387 [1]
Default: 0 (Disabled)
Access: 2 Path: Communication>Datalinks
See also:
Vista de pagina 174
1 2 ... 170 171 172 173 174 175 176 177 178 179 180 ... 273 274

Comentarios a estos manuales

Sin comentarios