Parameter Descriptions
11-63
Current state of the digital outputs.
Present operating temperature of the drive power section.
Accumulated percentage of drive overload. Continuously operating
the drive over 100% of its rating will increase this value to 100% and
cause a drive fault.
217 Dig Out Status
Range: See figure 11.24
Default: Read Only
Access: 2 Path: Utility>Diagnostics
Inputs & Outputs>Digital Outputs
See also: 380-384
Figure 11.24 – Dig Out Status (217)
0
xx
0
xxxxxxxxxxxx
10 01234567891112131415
1
=Output Energized
0
=Output De-energized
x =Reserved
Bit #
Digital Out1
Digital Out2
Nibble 1Nibble 2Nibble 3Nibble 4
218 Drive Temp
Range: -/+100 deg C [0.1 deg C]
Default: Read Only
Access: 2 Path: Utility>Diagnostics
See also:
219 Drive OL Count
Range: 0.0 to 100.0% [0.1%]
Default: Read Only
Access: 2 Path: Utility>Diagnostics
See also: 150