11-38
SP600 AC Drive User Manual
Defines the current limit value when Current Lmt Sel (147) = Cur
Lim Val.
Sets the responsiveness of the current limit.
Selects the drive’s response to increasing drive temperature. The
drive could reduce current limit, PWM carrier, or both. A fault or
alarm will be activated if an overload is detected.
Sets the carrier frequency for the PWM output. Drive derating may
occur at higher carrier frequencies. For derating information, refer to
Appendix A.
148 Current Lmt Val
Range: Based on Drive Type [0.1 Amps]
Default: Based on Drive Type (approx. 150% of Rated Amps)
Access: 0 Path: Dynamic Control>Load Limits
See also: 147, 149
149 Current Lmt Gain
Range: 0 to 5000 [1]
Default: 250
Access: 2 Path: Dynamic Control>Load Limits
See also: 147, 148
150 Drive OL Mode
Range: 0 = Disabled
1 = Reduce CLim
2 = Reduce PWM
3 = Both-PWM 1st
Default: 3 = Both-PWM 1st
Access: 1 Path: Dynamic Control>Load Limits
See also: 219
151 CarrierFrequency
Range: 2 - 10 kHz [1 kHz]
Default: 4 kHz
2 kHz (248 amp drives only)
Access: 0 Path: Dynamic Control>Load Limits
See also: 146, 149