Rockwell Automation Publication 2071-RM001B-EN-P - April 2013 101
Standard Drive Parameters Appendix A
Group 7 - Manufacturing Settings
This parameter group includes product settings that are programmed during the
manufacturing process.
Group 7 - Manufacturing Settings are programmed at the factory.
Do not modify these settings, as they provide a common drive setup that is
useful when you do either of the following:
Develop a drive system or troubleshooting a drive.
Seek assistance through Rockwell Automation Technical Support.
[Pr - 7.00] Drive Capacity
Ultraware Name Drive Model
Range 50…1500
Default Factory settings determine default.
Units W
When Enabled Servo-Off -> Setting -> After power cycle (ENG mode)
Applicable Operating Mode All
[Pr - 7.01] DC Bus Voltage Offset
Ultraware Name Calibration: DC Bus Voltage Offset
Range -100…100
Default 0
Units V
When Enabled Servo-Off -> Setting -> After power cycle (ENG mode)
Applicable Operating Mode All
[Pr - 7.02] Reserved
When Enabled Reserved for future use.
[Pr - 7.03] Analog Monitor Output CH1 Offset
Ultraware Name Calibration: Analog Output CH1 Offset
Range -1000…1000
Default 0
Units mV
When Enabled Servo-Off -> Setting -> After power cycle, (ENG mode)
Applicable Operating Mode All