74 Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
Appendix A Standard Drive Parameters
[Pr - 1.21] Current Regulator Bandwidth Reduction Scale
Ultraware Name Main Current Regulator Gains: Gain
Range Value Description
0x0 High bandwidth
0x1 Medium bandwidth
(0.6667 * high)
0x2 Low bandwidth (0.3334 *
high)
Default 0x1
When Enabled All
Applicable Operating Mode Immediately
Modbus Address 121
[Pr - 1.22] On-line Vibration Mode
Data Size 1 digits
Digit 0 On-line Vibration Suppression Mode
Ultraware Name On-line Vibration Suppression Mode
Range Value Description
0x0 Disable
0x1 Normal and High Velocity
Mode
0x2 Slow Velocity Mode
without initial value
Default 0x0
Digit 1 On-line Vibration Suppression Gain
Ultraware Name On-line Vibration Suppression Gain
Range Value Description
0x0 Low
0x1 High
Default 0x0
When Enabled All
Applicable Operating Mode Servo-Off -> Setting
Modbus Address 122
Comentarios a estos manuales