Rockwell-automation 2071-Axx Kinetix 3 Component Servo Drive Serial Ho Manual de usuario Pagina 68

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 146
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 67
68 Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
Appendix A Standard Drive Parameters
[Pr - 1.04] Velocity Regulator D gain
Ultraware Name Main Velocity Regulator Gains: Derivative Gain
Range 0…1000
Default 0
Units -
When Enabled Immediately
Applicable Operating Mode Follower, Analog Speed, Preset
Modbus Address 104
[Pr - 1.05] Velocity Error Filter
Ultraware Name Calibration: Error Filter Bandwidth
Range 0…2500
Default 30
Units Hz
When Enabled Immediately
Applicable Operating Mode Follower, Analog Speed, Preset
Modbus Address 105
[Pr - 1.06] Position Regulator Kp Gain
Ultraware Name Main Position Regulator Gains: Kp
Range 0…700
Default 20
Units Hz
When Enabled Immediately
Applicable Operating Mode Follower, Analog Speed, Preset
Modbus Address 106
Vista de pagina 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 145 146

Comentarios a estos manuales

Sin comentarios