Rockwell Automation Publication 2071-RM001B-EN-P - April 2013 55
Standard Drive Parameters Appendix A
[Pr - 0.07] Drive Address
Applicable Operating Mode All
Ultraware Name Drive Address
Range 1…248
Default 248
When Enabled Immediately
Applicable Operating Mode All
Modbus Address 8
[Pr - 0.08] Password
Applicable Operating Mode All
Ultraware Name Drive Password
Range 0…9999
Usage Note. Unprotected Code: 777
When Enabled Immediately
Applicable Operating Mode All
Modbus Address 9
[Pr - 0.09] Serial Port Configuration
Applicable Operating Mode All
Data Size 4 digits
Digit 0 Baud Rate
Ultraware Name Baud Rate
Range Value Description
0x0 9600 bps
0x1 14400 bps
0x2 19200 bps
0x3 38400 bps
0x4 56000 bps
0x5 57600 bps
Default 0x5 for Ultraware connection
0x2 for 1203-USB connection
Digit 1 Data bits, Parity, Stop bit
Ultraware Name Data bits, Parity, Stop bit
Range Value Description
0x0 8, No, 1
0x1 8, Even, 1
0x2 8, Odd, 1
0x3 8, No, 2
0x4 8, Even, 2
0x5 8, Odd, 2