Rockwell Automation Publication 2071-RM001B-EN-P - April 2013 59
Standard Drive Parameters Appendix A
[Pr - 0.15] Allocation of Input Signals 6
Data Size 4 digits
Digit Description Default Unmapped IO
Status
0Reset multi-turn data of absolute
encoder (R_ABS)
0x0 OFF
1 Gain bank select (BANK_SEL) 0x0 OFF
2Reserved 0x0OFF
3Reserved 0x0OFF
When Enabled Servo-Off -> Setting
(1)
(1) Refer to Setting Values for Parameters [Pr - 0.10]…[Pr - 0.21] on page 61.
Applicable Operating Mode All
Modbus Address 16
[Pr - 0.16] Allocation of Input Signals 7
Data Size 4 digits
Digit Description Default Unmapped IO
Status
0 Home sensor (H_SENS) 0x0 OFF
1 Start homing (SHOME) 0x0 OFF
2 Stop indexing (STOP) 0x0 OFF
3 Pause indexing (PAUSE) 0x0 OFF
When Enabled Servo-Off -> Setting
(1)
(1) Refer to Setting Values for Parameters [Pr - 0.10]…[Pr - 0.21] on page 61.
Applicable Operating Mode Indexing
Modbus Address 17
[Pr - 0.17] Allocation of Input Signals 8
Data Size 4 digits
Digit Description Default Unmapped IO
Status
0 Index select 0 input (I_SEL0) 0x0 OFF
1 Index select 1 input (I_SEL1) 0x0 OFF
2 Index select 2 input (I_SEL2) 0x0 OFF
3 Index select 3 input (I_SEL3) 0x0 OFF
When Enabled Servo-Off -> Setting
(1)
(1) Refer to Setting Values for Parameters [Pr - 0.10]…[Pr - 0.21] on page 61.
Applicable Operating Mode Indexing
Modbus Address 18