56 Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
Appendix A Standard Drive Parameters
Default 0x0
Digit 2 Protocol
Ultraware Name Protocol
Range Value Description
0x0 ASCII
0x1 Modbus-RTU
Default 0 for Ultraware connection
1 for 1203-USB connection
Digit 3 Communication Method
Ultraware Name Communication Method
Range Value Description
0 0x0 RS232
1 Ox1 RS485
Default 0 for Ultraware connection
1 for 1203-USB connection
When Enabled Immediately
Applicable Operating Mode All
Modbus Address 10
[Pr - 0.10] Allocation of Input Signals 1
Range for all digits 0…B, where 0 is Off, B is On and 1…A are digital inputs
Data Size 4 digits
Digit Description Default Unmapped IO
Status
0 Drive enable (SV-ON) 0x1 ON
1 Positive overtravel (P-OT) 0xb ON
2 Negative overtravel (N-OT) 0xb ON
3 Integrator inhibit (CON) 0x4 OFF
When Enabled Servo-Off -> Setting
(1)
(1) Refer to Setting Values for Parameters [Pr - 0.10]…[Pr - 0.21] on page 61.
Applicable Operating Mode All
Modbus Address 11
[Pr - 0.09] Serial Port Configuration (continued)